  • Power down and de-energize the equipment according to manufacturer procedures.
  • Disconnect the cable or serviceable connector and inspect for oxidation, contamination, damaged plating, bent contacts, weak retention, moisture or heat damage.
  • Replace physically damaged, burned, deeply pitted or mechanically defective connectors.
  • Apply a small controlled amount of DeoxIT Original to the serviceable metal contact.
  • Mate/un-mate the connector several times where appropriate to help distribute the cleaner and displace contamination.
  • Wipe accessible loosened contamination and excess product with lint-free material.
  • For suitable clean, gold-plated contacts, apply a very light amount of DeoxIT Gold if desired. For suitable exposed severe-environment contacts, use DeoxIT Shield as appropriate.
  • Restore cable strain relief, boots, caps, seals and weatherproofing.
  • Reconnect, restore power and verify the complete signal path.
  • DeoxIT Original — cleaning/rejuvenation of serviceable metal contacts
  • DeoxIT Gold — suitable clean plated/precious-metal low-level contacts
  • DeoxIT Shield — suitable exposed/severe-environment contacts
  • DeoxIT Grease — selected compatible electrical and mechanical applications
  • Precision needle, brush and pen applicators
  • Lint-free swabs and wipes
  • Small nylon/ESD-safe brushes
  • Inspection light and magnification device
  • Digital multimeter
  • Audio cable tester
  • Network/copper cable tester
  • Fiber inspection/cleaning tools kept separate from contact chemicals
  • OEM-approved replacement connectors, boots, caps and strain-relief hardware
  • Patch bays and frequently mated studio connections
  • Touring stage boxes, multi-pins and road-system connectors
  • Broadcast truck and field-production connections
  • Stadium and arena equipment rooms
  • Outdoor A/V equipment
  • Microphone and intercom connectors
  • High-use equipment-rack patching
  • Rental-house equipment and cable inventories
  • Legacy A/V equipment with serviceable oxidized connectors

Audio/video systems depend on large numbers of low-level analog, digital, RF, network, control and power connections. Oxidation, contamination, fretting, repeated mating, humidity, salt air, dust, smoke, vibration and handling can increase contact resistance or create intermittent connections, resulting in:

  • Clicks, pops, crackle, hum or intermittent audio
  • One channel cutting in and out
  • Noisy microphone or instrument signals
  • Video dropouts, sparkles, black screens or intermittent sync
  • Network and control failures
  • Intermittent camera, intercom or communications connections
  • Unreliable patch bays, stage boxes and multicore systems
  • Equipment that works only when a connector or cable is moved
  • False troubleshooting conclusions that lead to unnecessary cable, module or equipment replacement
  • Selected electrical connectors where the manufacturer permits a compatible protective/lubricating grease
  • Battery and charging hardware where appropriate for the contact design
  • Threaded connector shells and mechanical coupling hardware where electrical performance is not compromised
  • Rack hardware, latches, hinges and mechanical interfaces subject to corrosion
  • Outdoor mechanical metal-to-metal interfaces
  • Cable-reel, case and equipment mechanical hardware where compatible lubrication is useful

Do not apply grease indiscriminately to precision low-level signal contacts, optical interfaces or connector surfaces where the connector manufacturer specifies a dry mating interface.